Schneider Electric

Schneider Electric EX15T3HFNLP Transformer, dry type, DOE 2016, 15kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 18K, 115C rise, K13

(No reviews yet) Write a Review
SKU:
EX15T3HFNLP
MPN:
EX15T3HFNLP
Condition:
New
Box Number:
18K
Sustainable Offer Status:
Green Premium product
Efficiency:
98.24 % at 35 % load factor , 75.0°C
Percentage Impedance Voltage:
0.00018
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Device Application:
low voltage electrical distribution
Electrical Connection:
2 Hole Nema Pad primary 11.1 mm || 2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm
Product Or Component Type:
transformer
Eu Rohs Directive:
Compliant
Temperature Rise:
115°C || 220°C insulated
[Ipk] Rated Peak Withstand Current:
2.4 kA
Device Short Name:
DOE 2016
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP1604028EN
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Rated Operational Power In Va:
15 kVA
Net Weight:
181.44 kg
Secondary Voltage:
208Y/120 V
Continuous Thermal Current Rating Factor:
257.805015136 16.6 % || 286.18149999999997 25 % || 438.442 50 % || 692.2094999999999 75 % || 1047.484 1.0 %
Phase:
3 phase
Network Frequency:
60 Hz
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Ambient Air Temperature For Operation:
40-40°C
Tap Loss:
69.0 no load (core loss) || 238.0 load loss (coil loss)
Primary Voltage:
480 V delta
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Country of Origin:
Mexico
Material:
aluminium
Reach Free Of Svhc:
Yes
Rohs Exemption Information:
Yes
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18K || wall, with 7400WMB18K20K
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Circularity Profile:
N/A
Noise Level:
6 dB NEMA ST-20 || 39 dB
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS18K || UL type 3R, with 7400WS18K
X/R Ratio:
0.49
Transformer Type:
energy efficient
Weight:
181.44 kg
Average Ambient Air Temperature For Operation:
30°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Type Of Cooling:
natural convection
Depth:
533 mm
Halogen Content Performance:
Halogen free plastic parts product
Range Of Product:
Square D
[Uimp] Rated Impulse Withstand Voltage:
10 kV
$4,176.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 115 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.