Schneider Electric

Schneider Electric EX225T3HB Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 25J, 80C rise

(No reviews yet) Write a Review
SKU:
EX225T3HB
MPN:
EX225T3HB
Condition:
New
Pvc Free:
Yes
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Environmental Disclosure:
ENVPEP1604028EN
[Ipk] Rated Peak Withstand Current:
19.3 kA
Product Or Component Type:
transformer
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Net Weight:
843.68 kg
Sustainable Offer Status:
Green Premium product
Range Of Product:
Square D
Material:
aluminium
Tap Loss:
479.0 no load (core loss) || 2012.0 load loss (coil loss)
Mercury Free:
Yes
Device Short Name:
DOE 2016
Weight:
843.68 kg
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm
Secondary Voltage:
208Y/120 V
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Toxic Heavy Metal Free:
Yes
Rated Operational Power In Va:
225 kVA
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
X/R Ratio:
3.47
Ambient Air Temperature For Operation:
40-40°C
Circularity Profile:
N/A
Halogen Content Performance:
Halogen free plastic parts product
Depth:
832 mm
Efficiency:
99.11 % at 35 % load factor , 75.0°C
Temperature Rise:
80°C || 220°C insulated
Continuous Thermal Current Rating Factor:
1823.594287723424 16.6 % || 2063.4928744999997 25 % || 3350.7234439999997 50 % || 5496.107726499999 75 % || 8499.645722 1.0 %
Network Frequency:
60 Hz
Mounting Support:
floor || floor, with 7400FMB
Eu Rohs Directive:
Compliant
Noise Level:
6 dB NEMA ST-20 || 49 dB
Transformer Type:
energy efficient
Percentage Reactance:
0.00031
Box Number:
25J
Reach Free Of Svhc:
Yes
Average Ambient Air Temperature For Operation:
30°C
Country of Origin:
United States
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J
Phase:
3 phase
Device Application:
low voltage electrical distribution
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Primary Voltage:
480 V delta
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rohs Exemption Information:
Yes
Percentage Impedance Voltage:
0.00032
$19,641.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose