Schneider Electric

Schneider Electric EX225T3HFCU Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 24J, 115C rise, Cu

(No reviews yet) Write a Review
SKU:
EX225T3HFCU
MPN:
EX225T3HFCU
Condition:
New
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Device Short Name:
DOE 2016
Box Number:
24J
Sustainable Offer Status:
Green Premium product
Toxic Heavy Metal Free:
Yes
Ambient Air Temperature For Operation:
40-40°C
Primary Voltage:
480 V delta
Material:
copper
Net Weight:
700.8 kg
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Depth:
832 mm
Temperature Rise:
115°C || 220°C insulated
Percentage Reactance:
0.000662
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm
X/R Ratio:
3.85
Rated Operational Power In Va:
225 kVA
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Transformer Type:
energy efficient
Range Of Product:
Square D
Noise Level:
6 dB NEMA ST-20 || 49 dB
Continuous Thermal Current Rating Factor:
1503 16.6 % || 1962 25 % || 4441 50 % || 8572 75 % || 14355 100 %
Efficiency:
99.06 % at 35 % load factor , 75.0°C
Reach Free Of Svhc:
Yes
Rohs Exemption Information:
Yes
Network Frequency:
60 Hz
Weight:
700.8 kg
Environmental Disclosure:
ENVPEP1604027EN
Percentage Impedance Voltage:
0.068
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS25J || UL type 3R, with 7400WS25J
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Secondary Voltage:
208Y/120 V
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ipk] Rated Peak Withstand Current:
9.2 kA
Phase:
3 phase
Mercury Free:
Yes
Tap Loss:
333 no load (core loss) || 3874 load loss (coil loss)
Average Ambient Air Temperature For Operation:
30°C
Eu Rohs Directive:
Compliant
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Type Of Cooling:
natural convection
Mounting Support:
floor || floor, with 7400FMB
Product Or Component Type:
transformer
Circularity Profile:
N/A
Country of Origin:
Mexico
Device Application:
low voltage electrical distribution
Pvc Free:
Yes
$23,189.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 115 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose