Schneider Electric

Schneider Electric EX225T3HIS Transformer, dry type, DOE 2016, 225kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 25J, 150C rise, Shielded

(No reviews yet) Write a Review
SKU:
EX225T3HIS
MPN:
EX225T3HIS
Condition:
New
Reach Free Of Svhc:
Yes
Type Of Cooling:
natural convection
Phase:
3 phase
Device Short Name:
DOE 2016
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Network Frequency:
60 Hz
Temperature Rise:
150°C || 220°C insulated
Device Application:
low voltage electrical distribution
Pvc Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Material:
aluminium
Secondary Voltage:
208Y/120 V
Rohs Exemption Information:
Yes
Percentage Impedance Voltage:
0.00045
Mercury Free:
Yes
Toxic Heavy Metal Free:
Yes
Range Of Product:
Square D
Transformer Type:
energy efficient
Environmental Disclosure:
ENVPEP1604028EN
Percentage Reactance:
0.000399
Rated Operational Power In Va:
225 kVA
Primary Voltage:
480 V delta
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Circularity Profile:
N/A
Country of Origin:
United States
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Product Or Component Type:
transformer
Halogen Content Performance:
Halogen free plastic parts product
[Uimp] Rated Impulse Withstand Voltage:
10.0 kV
Box Number:
25J
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant
$13,342.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 225kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.94% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.