Schneider Electric EX500T63HCT Transformer, dry type, DOE 2016, 500kVA, 3 phase, 480V delta primary, 240V delta secondary, 30J, 150C rise, 120V ctr

(No reviews yet) Write a Review
SKU:
EX500T63HCT
MPN:
EX500T63HCT
Condition:
New
Country of Origin:
United States
Device Short Name:
DOE 2016
Continuous Thermal Current Rating Factor:
2606.866483599656 16.6 % || 3489.554971625 25 % || 8225.8213265 50 % || 16119.598584624999 75 % || 27170.886745999996 100 %
Transformer Type:
energy efficient
Halogen Content Performance:
Halogen free plastic parts product
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS30J || UL type 3R, with 7400WS30J
Environmental Disclosure:
ENVPEP1604028EN
Secondary Voltage:
240 V delta || centre tap 120 V
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Device Application:
low voltage electrical distribution
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Box Number:
30J
Rated Operational Power In Va:
500 kVA
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
X/R Ratio:
3.9
Primary Voltage:
480 V delta
Percentage Reactance:
0.000577
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Network Frequency:
60 Hz
Range Of Product:
Square D
Average Ambient Air Temperature For Operation:
30°C
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm
Depth:
963 mm
Noise Level:
6 dB NEMA ST-20 || 56 dB
Efficiency:
99.26 % at 35 % load factor , 75.0°C
Mounting Support:
floor || floor, with 7400FMB
Circularity Profile:
N/A
[Ipk] Rated Peak Withstand Current:
10.1 kA
Net Weight:
1322.22 kg
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Phase:
3 phase
Percentage Impedance Voltage:
0.0006
Tap Loss:
560.0 no load (core loss) || 7403.0 load loss (coil loss)
Type Of Cooling:
natural convection
Product Or Component Type:
transformer
Temperature Rise:
150°C || 220°C insulated
Reach Free Of Svhc:
Yes
Material:
aluminium
Number Of Tap-Offs:
2 2.5 % FCAN || 2 2.5 % FCBN
Sustainable Offer Status:
Green Premium product
Pvc Free:
Yes
Ambient Air Temperature For Operation:
40-40°C
$37,261.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 500kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 99.14% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.