Schneider Electric

Schneider Electric EX500T68H Transformer, dry type, DOE 2016, 500kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 30J, 150C rise

(No reviews yet) Write a Review
SKU:
EX500T68H
MPN:
EX500T68H
Condition:
New
Reach Free Of Svhc:
Yes
Primary Voltage:
480 V delta
Transformer Type:
energy efficient
Sustainable Offer Status:
Green Premium product
Net Weight:
1322.22 kg
Depth:
963 mm
Toxic Heavy Metal Free:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS30J || UL type 3R, with 7400WS30J
Ambient Air Temperature For Operation:
40-40°C
X/R Ratio:
3.58
Noise Level:
6 dB NEMA ST-20 || 56 dB
Tap Loss:
672.0 no load (core loss) || 6617.0 load loss (coil loss)
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Product Or Component Type:
transformer
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP1604028EN
Device Application:
low voltage electrical distribution
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Device Short Name:
DOE 2016
Rohs Exemption Information:
Yes
Continuous Thermal Current Rating Factor:
2915.122749427384 16.6 % || 3704.0933998749997 25 % || 7937.4953275 50 % || 14993.165206874999 75 % || 24871.103037999997 100 %
Eu Rohs Directive:
Compliant
Country of Origin:
Mexico
Percentage Reactance:
0.000474
Range Of Product:
Square D
Pvc Free:
Yes
Average Ambient Air Temperature For Operation:
30°C
Halogen Content Performance:
Halogen free plastic parts product
Efficiency:
99.24 % at 35 % load factor , 75.0°C
Type Of Cooling:
natural convection
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile:
N/A
Temperature Rise:
150°C || 220°C insulated
Secondary Voltage:
208Y/120 V
Rated Operational Power In Va:
500 kVA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Box Number:
30J
Phase:
3 phase
[Ipk] Rated Peak Withstand Current:
28.2 kA
Network Frequency:
60 Hz
Percentage Impedance Voltage:
0.00049
Material:
aluminium
Mounting Support:
floor || floor, with 7400FMB
Weight:
1322.22 kg
Number Of Tap-Offs:
2 2.5 % FCAN || 2 2.5 % FCBN
$23,716.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 500kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 99.14% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose