Schneider Electric

Schneider Electric EX500T68HFCU Transformer, dry type, DOE 2016, 500kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 30J, 115C rise, Cu

(No reviews yet) Write a Review
SKU:
EX500T68HFCU
MPN:
EX500T68HFCU
Condition:
New
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Device Application:
low voltage electrical distribution
Rated Operational Power In Va:
500 kVA
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Operation:
40-40°C
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Depth:
963 mm
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Temperature Rise:
115°C || 220°C insulated
Country of Origin:
United States
Circularity Profile:
N/A
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Noise Level:
6 dB NEMA ST-20 || 56 dB
[Ipk] Rated Peak Withstand Current:
29.2 kA
Transformer Type:
energy efficient
Rohs Exemption Information:
Yes
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1604027EN
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm
Box Number:
30J
Product Or Component Type:
transformer
Network Frequency:
60 Hz
Range Of Product:
Square D
Device Short Name:
DOE 2016
Material:
copper
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Mounting Support:
floor || floor, with 7400FMB
Pvc Free:
Yes
Net Weight:
1680.56 kg
Phase:
3 phase
Weight:
1680.56 kg
Number Of Tap-Offs:
2 2.5 % FCAN || 2 2.5 % FCBN
Primary Voltage:
480 V delta
Type Of Cooling:
natural convection
Mercury Free:
Yes
Degree Of Protection:
UL type 1 || UL type 2, with 7400DS30J || UL type 3R, with 7400WS30J
Average Ambient Air Temperature For Operation:
30°C
Secondary Voltage:
208Y/120 V
Toxic Heavy Metal Free:
Yes
$43,749.00

Description

EX three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 500kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 115 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 99.14% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 1 for indoor installation, field convertible to Type 2 via dripshield for indoor applications with dropping water or to Type 3R via weathershield for outdoor installation. The transformer's open bottom design limits the units to floor mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose