Schneider Electric

Schneider Electric EXN112T3155H Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 240V delta primary, 480Y/277V secondary, 21M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN112T3155H
MPN:
EXN112T3155H
Condition:
New
Number Of Mounting Holes:
4 Ø: 13 mm
Rated Operational Power In Va:
112.5 kVA
Temperature Rise:
150°C || 220°C insulated
Inrush Current:
3031 A
Average Ambient Air Temperature For Operation:
30°C
Noise Level:
44 dB || 6 dB NEMA ST-20
Phase:
3 phase
Device Application:
low voltage electrical distribution
Percentage Reactance:
0.03
Material:
aluminium
Tap Loss:
221 no load (core loss) || 2683 load loss (coil loss)
[Ipk] Rated Peak Withstand Current:
3.69 kA
Box Number:
21M
Network Frequency:
60 Hz
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - HO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
X/R Ratio:
1.59
Continuous Thermal Current Rating Factor:
1008 16.6 % || 1326 25 % || 3043 50 % || 5904 75 % || 9909 100 %
Depth:
722 mm
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Device Short Name:
DOE 2016
Product Or Component Type:
transformer
Primary Voltage:
240 V delta
Weight:
333.39 kg
Transformer Type:
energy efficient
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Net Weight:
333.39 kg
Range Of Product:
Square D
Type Of Cooling:
natural convection
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Ambient Air Temperature For Operation:
40-40°C
Secondary Voltage:
480Y/277 V
Primary Operational Current:
270.63-270.63 A 135.32 A 112.5 kVA
Percentage Impedance Voltage:
0.0367
Country of Origin:
Mexico
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
Efficiency:
98.77 % at 35 % load factor , 75.0°C
$9,621.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 208V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.