Schneider Electric

Schneider Electric EXN112T3156H Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 240V delta primary, 208Y/120V secondary, 21M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN112T3156H
MPN:
EXN112T3156H
Condition:
New
Country of Origin:
United States
Depth:
722 mm
Network Frequency:
60 Hz
Weight:
367.86 kg
Percentage Impedance Voltage:
0.0348
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Device Short Name:
DOE 2016
Ambient Air Temperature For Operation:
40-40°C
Primary Operational Current:
270.63-270.63 A 312.27 A 112.5 kVA
Transformer Type:
energy efficient
Continuous Thermal Current Rating Factor:
1048 16.6 % || 1350 25 % || 2986 50 % || 5711 75 % || 9527 100 %
Secondary Voltage:
208Y/120 V
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
Efficiency:
98.77 % at 35 % load factor , 75.0°C
Inrush Current:
2958 A
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Temperature Rise:
150°C || 220°C insulated
Type Of Cooling:
natural convection
Material:
aluminium
Tap Loss:
236 no load (core loss) || 2556 load loss (coil loss)
Percentage Reactance:
0.0287
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm
Phase:
3 phase
Net Weight:
367.86 kg
Average Ambient Air Temperature For Operation:
30°C
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Range Of Product:
Square D
[Ipk] Rated Peak Withstand Current:
8.97 kA
Primary Voltage:
240 V delta
Noise Level:
44 dB || 6 dB NEMA ST-20
Device Application:
low voltage electrical distribution
X/R Ratio:
1.61
Rated Operational Power In Va:
112.5 kVA
Box Number:
21M
Product Or Component Type:
transformer
Number Of Mounting Holes:
4 Ø: 13 mm
$9,621.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 208V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.