Schneider Electric

Schneider Electric EXN112T3HBCU Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 21M, 80C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN112T3HBCU
MPN:
EXN112T3HBCU
Condition:
New
Weight:
519.82 kg
Sustainable Offer Status:
Green Premium product
Secondary Voltage:
208Y/120 V
Country of Origin:
Mexico
Toxic Heavy Metal Free:
Yes
Environmental Disclosure:
ENVPEP1604027EN
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Transformer Type:
energy efficient
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Depth:
722 mm
Product Or Component Type:
transformer
Type Of Cooling:
natural convection
Circularity Profile:
N/A
Device Application:
low voltage electrical distribution
Tap Loss:
227 no load (core loss) || 1466 load loss (coil loss)
Average Ambient Air Temperature For Operation:
30°C
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Inrush Current:
1329 A
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Material:
copper
Ambient Air Temperature For Operation:
40-40°C
Temperature Rise:
80°C || 220°C insulated
Width:
795 mm
Network Frequency:
60 Hz
X/R Ratio:
2.9
Net Weight:
519.82 kg
Rated Operational Power In Va:
112.5 kVA
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Percentage Impedance Voltage:
0.0376
Rohs Exemption Information:
Yes
Box Number:
21M
Noise Level:
47 dB || 3 dB NEMA ST-20
Percentage Reactance:
0.0355
Number Of Mounting Holes:
4 Ø: 13 mm
Phase:
3 phase
Efficiency:
99.00 % at 35 % load factor , 75.0°C
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Continuous Thermal Current Rating Factor:
914 16.6 % || 1087 25 % || 2025 50 % || 3588 75 % || 5777 100 %
Primary Voltage:
480 V delta
Pvc Free:
Yes
[Ipk] Rated Peak Withstand Current:
8.80 kA
Eu Rohs Directive:
Compliant
Primary Operational Current:
135.32-135.32 A 312.27 A 112.5 kVA
Range Of Product:
Square D
Device Short Name:
DOE 2016
Reach Regulation:
Free of Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
$16,923.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.