Schneider Electric

Schneider Electric EXN112T3HCU Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 21M, 150C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN112T3HCU
MPN:
EXN112T3HCU
Condition:
New
Rohs Exemption Information:
Yes
Country of Origin:
Mexico
Net Weight:
441.80 kg
[Ipk] Rated Peak Withstand Current:
9.55 kA
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Average Ambient Air Temperature For Operation:
30°C
Network Frequency:
60 Hz
Percentage Impedance Voltage:
0.0327
Inrush Current:
1563 A
Primary Operational Current:
135.32-135.32 A 312.27 A 112.5 kVA
Product Or Component Type:
transformer
Device Short Name:
DOE 2016
Efficiency:
98.80 % at 35 % load factor , 75.0°C
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Number Of Mounting Holes:
4 Ø: 13 mm
Sustainable Offer Status:
Green Premium product
X/R Ratio:
1.39
Eu Rohs Directive:
Compliant
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Type Of Cooling:
natural convection
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Continuous Thermal Current Rating Factor:
1039 16.6 % || 1322 25 % || 2850 50 % || 5397 75 % || 8964 100 %
Transformer Type:
energy efficient
Depth:
722 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Secondary Voltage:
208Y/120 V
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Reach Free Of Svhc:
Yes
Temperature Rise:
150°C || 220°C insulated
Ambient Air Temperature For Operation:
40-40°C
Rated Operational Power In Va:
112.5 kVA
Material:
copper
Circularity Profile:
N/A
Percentage Reactance:
0.0267
Primary Voltage:
480 V delta
Weight:
441.80 kg
Device Application:
low voltage electrical distribution
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Mercury Free:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Noise Level:
44 dB || 6 dB NEMA ST-20
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP1604027EN
Box Number:
21M
Range Of Product:
Square D
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
$11,564.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose