New
Ambient Air Temperature For Operation:
40-40°C
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Primary Voltage:
480 V delta
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Continuous Thermal Current Rating Factor:
1015 16.6 % || 1316 25 % || 2942 50 % || 5652 75 % || 9445 100 %
Inrush Current:
1444 A
Noise Level:
47 dB || 3 dB NEMA ST-20
Country of Origin:
United States
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Average Ambient Air Temperature For Operation:
30°C
Secondary Voltage:
208Y/120 V
Number Of Mounting Holes:
4 Ø: 13 mm
Net Weight:
363.78 kg
Percentage Reactance:
0.03
Halogen Content Performance:
Halogen free plastic parts product
Box Number:
21M
Rated Operational Power In Va:
112.5 kVA
Material:
aluminium
Device Application:
low voltage electrical distribution
Primary Operational Current:
135.32-135.32 A 312.27 A 112.5 kVA
Network Frequency:
60 Hz
Tap Loss:
227 no load (core loss) || 2541 load loss (coil loss)
Weight:
363.78 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Reach Free Of Svhc:
Yes
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Circularity Profile:
N/A
X/R Ratio:
1.72
Depth:
722 mm
Efficiency:
98.79 % at 35 % load factor , 75.0°C
Toxic Heavy Metal Free:
Yes
[Ipk] Rated Peak Withstand Current:
8.44 kA
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Device Short Name:
DOE 2016
Phase:
3 phase
Type Of Cooling:
natural convection
Transformer Type:
energy efficient
Percentage Impedance Voltage:
0.037
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Range Of Product:
Square D
Rohs Exemption Information:
Yes
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
Product Or Component Type:
transformer
$10,323.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.