Schneider Electric

Schneider Electric EXN112T65HCU Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 600V delta primary, 208Y/120V secondary, 21M, 150C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN112T65HCU
MPN:
EXN112T65HCU
Condition:
New
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Number Of Mounting Holes:
4 Ø: 13 mm
Box Number:
21M
Ambient Air Temperature For Operation:
40-40°C
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Primary Operational Current:
108.25-108.25 A 312.27 A 112.5 kVA
Type Of Cooling:
natural convection
Efficiency:
98.81 % at 35 % load factor , 75.0°C
Rated Operational Power In Va:
112.5 kVA
Secondary Voltage:
208Y/120 V
[Ipk] Rated Peak Withstand Current:
9.55 kA
Depth:
722 mm
Continuous Thermal Current Rating Factor:
974 16.6 % || 1284 25 % || 2954 50 % || 5738 75 % || 9636 100 %
Product Or Component Type:
transformer
Country of Origin:
United States
Weight:
382.83 kg
Percentage Reactance:
0.024
Percentage Impedance Voltage:
0.0327
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Average Ambient Air Temperature For Operation:
30°C
Network Frequency:
60 Hz
Net Weight:
382.83 kg
Noise Level:
44 dB || 6 dB NEMA ST-20
Phase:
3 phase
Range Of Product:
Square D
Primary Voltage:
600 V delta
Temperature Rise:
150°C || 220°C insulated
X/R Ratio:
1.08
Tap Loss:
213 no load (core loss) || 2611 load loss (coil loss)
Device Application:
low voltage electrical distribution
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
Device Short Name:
DOE 2016
Transformer Type:
energy efficient
Inrush Current:
1354 A
Material:
copper
$15,033.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 600V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.