Schneider Electric

Schneider Electric EXN112T6HCT Transformer, dry type, DOE 2016, 112.5kVA, 3 phase, 480V delta primary, 240V delta secondary, 21M, 150C rise, 120V ctr

(No reviews yet) Write a Review
SKU:
EXN112T6HCT
MPN:
EXN112T6HCT
Condition:
New
Material:
aluminium
Reach Free Of Svhc:
Yes
Percentage Impedance Voltage:
0.0347
Continuous Thermal Current Rating Factor:
1008 16.6 % || 1300 25 % || 2876 50 % || 5502 75 % || 9197 100 %
Product Or Component Type:
transformer
Device Application:
low voltage electrical distribution
Transformer Type:
energy efficient
Depth:
722 mm
Percentage Reactance:
0.0277
Mercury Free:
Yes
[Ipk] Rated Peak Withstand Current:
7.80 kA
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
X/R Ratio:
1.46
Device Short Name:
DOE 2016
Eu Rohs Directive:
Compliant
Toxic Heavy Metal Free:
Yes
Primary Voltage:
480 V delta
Number Of Mounting Holes:
4 Ø: 13 mm
Tap Loss:
227 no load (core loss) || 2463 load loss (coil loss)
Average Ambient Air Temperature For Operation:
30°C
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS21M
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB21M
Box Number:
21M
Secondary Voltage:
240 V delta || centre tap 120 V
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rated Operational Power In Va:
112.5 kVA
Inrush Current:
1518 A
Network Frequency:
60 Hz
Ambient Air Temperature For Operation:
40-40°C
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Noise Level:
44 dB || 6 dB NEMA ST-20
Net Weight:
331.12 kg
Phase:
3 phase
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Type Of Cooling:
natural convection
Range Of Product:
Square D
Country of Origin:
Mexico
Rohs Exemption Information:
Yes
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Temperature Rise:
150°C || 220°C insulated
Efficiency:
98.81 % at 35 % load factor , 75.0°C
Weight:
331.12 kg
Primary Operational Current:
135.32-135.32 A 270.63 A 112.5 kVA
$7,772.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 112.5kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.74% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose