Schneider Electric

Schneider Electric EXN150T3HBCU Transformer, dry type, DOE 2016, 150kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 22M, 80C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN150T3HBCU
MPN:
EXN150T3HBCU
Condition:
New
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Device Short Name:
DOE 2016
Efficiency:
99.09 % at 35 % load factor , 75.0°C
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Weight:
645.92 kg
Primary Voltage:
480 V delta
Phase:
3 phase
Product Or Component Type:
transformer
Secondary Voltage:
208Y/120 V
Rohs Exemption Information:
Yes
Transformer Type:
energy efficient
Range Of Product:
Square D
Number Of Mounting Holes:
4 Ø: 13 mm
Depth:
827 mm
X/R Ratio:
3.91
Environmental Disclosure:
ENVPEP1604027EN
Continuous Thermal Current Rating Factor:
1193 16.6 % || 1456 25 % || 2877 50 % || 5246 75 % || 8561 100 %
Toxic Heavy Metal Free:
Yes
Average Ambient Air Temperature For Operation:
30°C
Country of Origin:
Mexico
Temperature Rise:
80°C || 220°C insulated
Electrical Connection:
6 Hole Nema Pad secondary 11.1 mm || 8 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Sustainable Offer Status:
Green Premium product
Primary Operational Current:
90.21-90.21 A 208.18 A 150 kVA
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Circularity Profile:
N/A
Inrush Current:
1332 A
Material:
copper
Noise Level:
49 dB || 7 dB
Tap Loss:
228 no load (core loss) || 2221 load loss (coil loss)
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22M
Ambient Air Temperature For Operation:
40-40°C
Device Application:
low voltage electrical distribution
Box Number:
22M
Reach Free Of Svhc:
Yes
Eu Rohs Directive:
Compliant
Rated Operational Power In Va:
150 kVA
Type Of Cooling:
natural convection
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Percentage Reactance:
0.0528
Net Weight:
645.92 kg
Pvc Free:
Yes
Network Frequency:
60 Hz
[Ipk] Rated Peak Withstand Current:
7.64 kA
$22,017.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.