Primary Operational Current:
180.42-180.42 A 416.36 A 150 kVA
Mercury Free:
Yes
Network Frequency:
60 Hz
Percentage Reactance:
0.0426
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Percentage Impedance Voltage:
0.0456
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Reach Free Of Svhc:
Yes
Ambient Air Temperature For Operation:
40-40°C
Toxic Heavy Metal Free:
Yes
Eu Rohs Directive:
Compliant
Pvc Free:
Yes
Material:
copper
Number Of Mounting Holes:
4 Ø: 13 mm
Depth:
827 mm
Device Application:
low voltage electrical distribution
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Country of Origin:
Mexico
Inrush Current:
1476 A
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22M
Range Of Product:
Square D
Average Ambient Air Temperature For Operation:
30°C
Continuous Thermal Current Rating Factor:
1163 16.6 % || 1496 25 % || 3290 50 % || 6281 75 % || 10468 100 %
Environmental Disclosure:
ENVPEP1604027EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
[Ipk] Rated Peak Withstand Current:
9.13 kA
Primary Voltage:
480 V delta
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
Rohs Exemption Information:
Yes
Temperature Rise:
115°C || 220°C insulated
Box Number:
22M
Phase:
3 phase
Height:
1031 mm
Net Weight:
591.03 kg
Transformer Type:
energy efficient
Tap Loss:
263 no load (core loss) || 2805 load loss (coil loss)
X/R Ratio:
2.39
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
transformer
Rated Operational Power In Va:
150 kVA
Noise Level:
47 dB || 3 dB NEMA ST-20
Weight:
591.03 kg
Device Short Name:
DOE 2016
Secondary Voltage:
208Y/120 V
Efficiency:
98.94 % at 35 % load factor , 75.0°C
Type Of Cooling:
natural convection
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
$18,711.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 115 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.