Schneider Electric

Schneider Electric EXN150T65H Transformer, dry type, DOE 2016, 150kVA, 3 phase, 600V delta primary, 208Y/120V secondary, 22M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN150T65H
MPN:
EXN150T65H
Condition:
New
Type Of Cooling:
natural convection
Product Or Component Type:
transformer
Temperature Rise:
150°C || 220°C insulated
Depth:
827 mm
Tap Loss:
301 no load (core loss) || 2819 load loss (coil loss)
Secondary Voltage:
208Y/120 V
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22M
Percentage Reactance:
0.0259
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Eu Rohs Directive:
Compliant
Weight:
454.50 kg
Halogen Content Performance:
Halogen free plastic parts product
Network Frequency:
60 Hz
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Number Of Mounting Holes:
4 Ø: 13 mm
Phase:
3 phase
Primary Voltage:
600 V delta
Environmental Disclosure:
ENVPEP1604028EN
Sustainable Offer Status:
Green Premium product
Primary Operational Current:
144.34-144.34 A 416.36 A 150 kVA
Net Weight:
454.50 kg
Rated Operational Power In Va:
150 kVA
Toxic Heavy Metal Free:
Yes
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Ambient Air Temperature For Operation:
40-40°C
Inrush Current:
1653 A
Rohs Exemption Information:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Transformer Type:
energy efficient
Country of Origin:
Mexico
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mercury Free:
Yes
Noise Level:
47 dB || 3 dB NEMA ST-20
Pvc Free:
Yes
X/R Ratio:
1.61
Average Ambient Air Temperature For Operation:
30°C
Percentage Impedance Voltage:
0.0314
Reach Free Of Svhc:
Yes
Device Short Name:
DOE 2016
Device Application:
low voltage electrical distribution
Continuous Thermal Current Rating Factor:
1294 16.6 % || 1628 25 % || 3432 50 % || 6438 75 % || 10646 100 %
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Efficiency:
98.90 % at 35 % load factor , 75.0°C
Box Number:
22M
[Ipk] Rated Peak Withstand Current:
13.26 kA
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
$12,483.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 600V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.