Schneider Electric EXN150T65HCU Transformer, dry type, DOE 2016, 150kVA, 3 phase, 600V delta primary, 208Y/120V secondary, 22M, 150C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN150T65HCU
MPN:
EXN150T65HCU
Condition:
New
Material:
copper
Secondary Voltage:
208Y/120 V
Phase:
3 phase
Net Weight:
540.68 kg
Network Frequency:
60 Hz
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Primary Voltage:
600 V delta
Country of Origin:
Mexico
Device Short Name:
DOE 2016
Average Ambient Air Temperature For Operation:
30°C
Inrush Current:
1060 A
[Ipk] Rated Peak Withstand Current:
7.96 kA
Transformer Type:
energy efficient
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Depth:
827 mm
Primary Operational Current:
144.34-144.34 A 416.36 A 150 kVA
Box Number:
22M
Product Or Component Type:
transformer
Percentage Reactance:
0.048
Temperature Rise:
150°C || 220°C insulated
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22M
Percentage Impedance Voltage:
0.0523
Type Of Cooling:
natural convection
Device Application:
low voltage electrical distribution
Number Of Mounting Holes:
4 Ø: 13 mm
Ambient Air Temperature For Operation:
40-40°C
Noise Level:
47 dB || 3 dB NEMA ST-20
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
X/R Ratio:
2.33
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm
Continuous Thermal Current Rating Factor:
1053 16.6 % || 1444 25 % || 3556 50 % || 7076 75 % || 12004 100 %
Weight:
540.68 kg
Tap Loss:
217 no load (core loss) || 3301 load loss (coil loss)
Rated Operational Power In Va:
150 kVA
Range Of Product:
Square D
Efficiency:
98.97 % at 35 % load factor , 75.0°C
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
$20,352.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 600V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.