Schneider Electric

Schneider Electric EXN150T6HCT Transformer, dry type, DOE 2016, 150kVA, 3 phase, 480V delta primary, 240V delta secondary, 22M, 150C rise, 120V ctr

(No reviews yet) Write a Review
SKU:
EXN150T6HCT
MPN:
EXN150T6HCT
Condition:
New
Primary Operational Current:
180.42-180.42 A 360.84 A 150 kVA
Eu Rohs Directive:
Compliant
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Noise Level:
47 dB || 3 dB NEMA ST-20
Ambient Air Temperature For Operation:
40-40°C
Toxic Heavy Metal Free:
Yes
Percentage Impedance Voltage:
0.0308
Weight:
456.77 kg
Continuous Thermal Current Rating Factor:
1302 16.6 % || 1624 25 % || 3365 50 % || 6267 75 % || 10329 100 %
Phase:
3 phase
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Material:
aluminium
Device Application:
low voltage electrical distribution
Transformer Type:
energy efficient
Mercury Free:
Yes
Inrush Current:
2053 A
Rated Operational Power In Va:
150 kVA
Device Short Name:
DOE 2016
Net Weight:
456.77 kg
Range Of Product:
Square D
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
Depth:
827 mm
Type Of Cooling:
natural convection
Box Number:
22M
Network Frequency:
60 Hz
Product Or Component Type:
transformer
Average Ambient Air Temperature For Operation:
30°C
Temperature Rise:
150°C || 220°C insulated
Number Of Mounting Holes:
4 Ø: 13 mm
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Secondary Voltage:
240 V delta || centre tap 120 V
Efficiency:
98.91 % at 35 % load factor , 75.0°C
Country of Origin:
Mexico
Reach Free Of Svhc:
Yes
[Ipk] Rated Peak Withstand Current:
11.72 kA
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Rohs Exemption Information:
Yes
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB22M
Percentage Reactance:
0.0257
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
X/R Ratio:
1.66
Primary Voltage:
480 V delta
Tap Loss:
306 no load (core loss) || 2721 load loss (coil loss)
$10,522.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 150kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.83% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.