Schneider Electric

Schneider Electric EXN15T1814H Transformer, dry type, DOE 2016, 15kVA, 3 phase, 480V delta primary, 480Y/277V secondary, 17M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN15T1814H
MPN:
EXN15T1814H
Condition:
New
Phase:
3 phase
Device Application:
low voltage electrical distribution
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB17M || wall, with 7400WMB17M
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Tap Loss:
51 no load (core loss) || 561 load loss (coil loss)
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Percentage Impedance Voltage:
0.0462
[Ipk] Rated Peak Withstand Current:
0.39 kA
Efficiency:
98.00 % at 35 % load factor , 75.0°C
Box Number:
17M
Continuous Thermal Current Rating Factor:
227 16.6 % || 294 25 % || 653 50 % || 1251 75 % || 2088 100 %
Ambient Air Temperature For Operation:
40-40°C
Primary Voltage:
480 V delta
Network Frequency:
60 Hz
Depth:
538 mm
Temperature Rise:
150°C || 220°C insulated
Noise Level:
6 dB NEMA ST-20 || 39 dB
Country of Origin:
United States
Transformer Type:
energy efficient
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Secondary Voltage:
480Y/277 V
Number Of Mounting Holes:
4 Ø: 13 mm
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Net Weight:
86.64 kg
Weight:
86.64 kg
Product Or Component Type:
transformer
Average Ambient Air Temperature For Operation:
30°C
Material:
aluminium
Percentage Reactance:
0.0277
X/R Ratio:
0.89
Device Short Name:
DOE 2016
Inrush Current:
207 A
Rated Operational Power In Va:
15 kVA
Type Of Cooling:
natural convection
Primary Operational Current:
18.04-18.04 A 18.04 A 15 kVA
Range Of Product:
Square D
$3,417.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 480V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.