Schneider Electric

Schneider Electric EXN15T3155H Transformer, dry type, DOE 2016, 15kVA, 3 phase, 240V delta primary, 480Y/277V secondary, 17M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN15T3155H
MPN:
EXN15T3155H
Condition:
New
Primary Operational Current:
36.08-36.08 A 18.04 A 15 kVA
[Ipk] Rated Peak Withstand Current:
0.90 kA
Depth:
538 mm
Net Weight:
86.64 kg
Network Frequency:
60 Hz
Range Of Product:
Square D
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - HO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Phase:
3 phase
Rated Operational Power In Va:
15 kVA
Average Ambient Air Temperature For Operation:
30°C
Country of Origin:
Mexico
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Primary Voltage:
240 V delta
X/R Ratio:
0.72
Percentage Reactance:
0.0212
Product Or Component Type:
transformer
Temperature Rise:
150°C || 220°C insulated
Continuous Thermal Current Rating Factor:
241 16.6 % || 308 25 % || 667 50 % || 1266 75 % || 2105 100 %
Percentage Impedance Voltage:
0.0401
Box Number:
17M
Inrush Current:
1089 A
Type Of Cooling:
natural convection
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
Secondary Voltage:
480Y/277 V
Noise Level:
6 dB NEMA ST-20 || 39 dB
Weight:
86.64 kg
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Transformer Type:
energy efficient
Tap Loss:
55 no load (core loss) || 562 load loss (coil loss)
Material:
aluminium
Ambient Air Temperature For Operation:
40-40°C
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB17M || wall, with 7400WMB17M
Efficiency:
97.94 % at 35 % load factor , 75.0°C
Number Of Mounting Holes:
4 Ø: 13 mm
Device Application:
low voltage electrical distribution
Device Short Name:
DOE 2016
$3,417.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 208V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.