Schneider Electric

Schneider Electric EXN15T3156H Transformer, dry type, DOE 2016, 15kVA, 3 phase, 240V delta primary, 208Y/120V secondary, 17M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN15T3156H
MPN:
EXN15T3156H
Condition:
New
Ambient Air Temperature For Operation:
40-40°C
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Primary Voltage:
240 V delta
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB17M || wall, with 7400WMB17M
Continuous Thermal Current Rating Factor:
237 16.6 % || 302 25 % || 656 50 % || 1246 75 % || 2071 100 %
Country of Origin:
Mexico
Number Of Mounting Holes:
4 Ø: 13 mm
Box Number:
17M
Inrush Current:
459 A
[Ipk] Rated Peak Withstand Current:
1.03 kA
Secondary Voltage:
208Y/120 V
Weight:
87.09 kg
Network Frequency:
60 Hz
X/R Ratio:
0.8
Rated Operational Power In Va:
15 kVA
Percentage Reactance:
0.0228
Temperature Rise:
150°C || 220°C insulated
Noise Level:
6 dB NEMA ST-20 || 39 dB
Range Of Product:
Square D
Efficiency:
97.96 % at 35 % load factor , 75.0°C
Average Ambient Air Temperature For Operation:
30°C
Depth:
538 mm
Product Or Component Type:
transformer
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Primary Operational Current:
36.08-36.08 A 18.04 A 15 kVA
Material:
aluminium
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Transformer Type:
energy efficient
Device Application:
low voltage electrical distribution
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
Phase:
3 phase
Type Of Cooling:
natural convection
Percentage Impedance Voltage:
0.0404
Net Weight:
87.09 kg
Tap Loss:
54 no load (core loss) || 553 load loss (coil loss)
Device Short Name:
DOE 2016
$3,417.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 208V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.