Schneider Electric

Schneider Electric EXN15T3HBCU Transformer, dry type, DOE 2016, 15kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 17M, 80C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN15T3HBCU
MPN:
EXN15T3HBCU
Condition:
New
Mercury Free:
Yes
Primary Voltage:
480 V delta
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS22M
Device Short Name:
DOE 2016
Eu Rohs Directive:
Compliant
Pvc Free:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Tap Loss:
51 no load (core loss) || 438 load loss (coil loss)
Secondary Voltage:
208Y/120 V
Range Of Product:
Square D
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB17M || wall, with 7400WMB17M
X/R Ratio:
1.23
Type Of Cooling:
natural convection
Percentage Impedance Voltage:
0.0453
Rated Operational Power In Va:
15 kVA
Noise Level:
6 dB NEMA ST-20 || 39 dB
Box Number:
17M
Network Frequency:
60 Hz
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Reach Free Of Svhc:
Yes
Environmental Disclosure:
ENVPEP1604027EN
Sustainable Offer Status:
Green Premium product
Net Weight:
106.59 kg
Inrush Current:
220 A
[Ipk] Rated Peak Withstand Current:
0.92 kA
Country of Origin:
Mexico
Weight:
106.59 kg
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Number Of Mounting Holes:
4 Ø: 13 mm
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Product Or Component Type:
transformer
Continuous Thermal Current Rating Factor:
216 16.6 % || 267 25 % || 548 50 % || 1015 75 % || 1669 100 %
Efficiency:
98.10 % at 35 % load factor , 75.0°C
Ambient Air Temperature For Operation:
40-40°C
Rohs Exemption Information:
Yes
Temperature Rise:
80°C || 220°C insulated
Device Application:
low voltage electrical distribution
Toxic Heavy Metal Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile:
N/A
Primary Operational Current:
18.04-18.04 A 41.64 A 15 kVA
Transformer Type:
energy efficient
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Phase:
3 phase
Material:
copper
$5,736.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 15kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 97.89% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.