Schneider Electric

Schneider Electric EXN30T3156H Transformer, dry type, DOE 2016, 30kVA, 3 phase, 240V delta primary, 208Y/120V secondary, 18M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN30T3156H
MPN:
EXN30T3156H
Condition:
New
Secondary Voltage:
208Y/120 V
Device Application:
low voltage electrical distribution
Phase:
3 phase
Percentage Impedance Voltage:
0.0322
Number Of Mounting Holes:
4 Ø: 13 mm
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Primary Operational Current:
72.17-72.17 A 83.27 A 30 kVA
X/R Ratio:
1.02
Net Weight:
164.65 kg
Box Number:
18M
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
Ambient Air Temperature For Operation:
40-40°C
Rated Operational Power In Va:
30 kVA
Material:
aluminium
Weight:
164.65 kg
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Temperature Rise:
150°C || 220°C insulated
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Noise Level:
6 dB NEMA ST-20 || 39 dB
Device Short Name:
DOE 2016
Inrush Current:
1222 A
Percentage Reactance:
0.0208
Country of Origin:
United States
Product Or Component Type:
transformer
Tap Loss:
99 no load (core loss) || 808 load loss (coil loss)
Network Frequency:
60 Hz
Efficiency:
98.23 % at 35 % load factor , 75.0°C
Continuous Thermal Current Rating Factor:
414 16.6 % || 510 25 % || 1027 50 % || 1889 75 % || 3095 100 %
Depth:
627 mm
Average Ambient Air Temperature For Operation:
30°C
Transformer Type:
energy efficient
[Ipk] Rated Peak Withstand Current:
2.59 kA
Primary Voltage:
240 V delta
Range Of Product:
Square D
Type Of Cooling:
natural convection
$4,146.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 30kVA, 208V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.23% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose