Schneider Electric

Schneider Electric EXN30T3HCUNLP Transformer, dry type, DOE 2016, 30kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 18M, 150C rise, Cu, K13

(No reviews yet) Write a Review
SKU:
EXN30T3HCUNLP
MPN:
EXN30T3HCUNLP
Condition:
New
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
Inrush Current:
581 A
Rohs Exemption Information:
Yes
Circularity Profile:
N/A
Ambient Air Temperature For Operation:
40-40°C
Percentage Impedance Voltage:
0.0306
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Mercury Free:
Yes
Country of Origin:
Mexico
Box Number:
18M
Primary Voltage:
480 V delta
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Material:
copper
Average Ambient Air Temperature For Operation:
30°C
Device Application:
low voltage electrical distribution
Net Weight:
184.61 kg
Continuous Thermal Current Rating Factor:
375 16.6 % || 459 25 % || 916 50 % || 1677 75 % || 2743 100 %
X/R Ratio:
1.04
Noise Level:
6 dB NEMA ST-20 || 39 dB
[Ipk] Rated Peak Withstand Current:
2.72 kA
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Efficiency:
98.48 % at 35 % load factor , 75.0°C
Rated Operational Power In Va:
30 kVA
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Primary Operational Current:
36.08-36.08 A 83.27 A 30 kVA
Transformer Type:
energy efficient
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Type Of Cooling:
natural convection
Reach Free Of Svhc:
Yes
Secondary Voltage:
208Y/120 V
Pvc Free:
Yes
Eu Rohs Directive:
Compliant
Tap Loss:
90 no load (core loss) || 714 load loss (coil loss)
Weight:
184.61 kg
Product Or Component Type:
transformer
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Device Short Name:
DOE 2016
Range Of Product:
Square D
Phase:
3 phase
Environmental Disclosure:
ENVPEP1604027EN
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Depth:
627 mm
Network Frequency:
60 Hz
Temperature Rise:
150°C || 220°C insulated
Toxic Heavy Metal Free:
Yes
$7,366.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 30kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.23% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.