Schneider Electric

Schneider Electric EXN30T3HNLP Transformer, dry type, DOE 2016, 30kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 18M, 150C rise, K13

(No reviews yet) Write a Review
SKU:
EXN30T3HNLP
MPN:
EXN30T3HNLP
Condition:
New
Eu Rohs Directive:
Compliant
Net Weight:
152.41 kg
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Rated Operational Power In Va:
30 kVA
Weight:
152.41 kg
Sustainable Offer Status:
Green Premium product
Depth:
627 mm
[Ipk] Rated Peak Withstand Current:
1.99 kA
Number Of Mounting Holes:
4 Ø: 13 mm
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Toxic Heavy Metal Free:
Yes
Reach Free Of Svhc:
Yes
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP1604028EN
Circularity Profile:
N/A
Device Short Name:
DOE 2016
Continuous Thermal Current Rating Factor:
378 16.6 % || 496 25 % || 1135 50 % || 2201 75 % || 3692 100 %
Network Frequency:
60 Hz
Phase:
3 phase
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Primary Operational Current:
180.42-180.42 A 416.36 A 150 kVA
Halogen Content Performance:
Halogen free plastic parts product
Country of Origin:
United States
Range Of Product:
Square D
Inrush Current:
420 A
Material:
aluminium
Percentage Reactance:
0.0264
Product Or Component Type:
transformer
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Transformer Type:
energy efficient
Temperature Rise:
150°C || 220°C insulated
Secondary Voltage:
208Y/120 V
Tap Loss:
83 no load (core loss) || 999 load loss (coil loss)
Average Ambient Air Temperature For Operation:
30°C
Noise Level:
6 dB NEMA ST-20 || 39 dB
Type Of Cooling:
natural convection
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Ambient Air Temperature For Operation:
40-40°C
X/R Ratio:
1.03
Box Number:
18M
Primary Voltage:
480 V delta
Efficiency:
98.29 % at 35 % load factor , 75.0°C
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - XO 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
$4,236.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 30kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.23% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.