Schneider Electric

Schneider Electric EXN30T6HCT Transformer, dry type, DOE 2016, 30kVA, 3 phase, 480V delta primary, 240V delta secondary, 18M, 150C rise, 120V ctr

(No reviews yet) Write a Review
SKU:
EXN30T6HCT
MPN:
EXN30T6HCT
Condition:
New
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Net Weight:
163.75 kg
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Type Of Cooling:
natural convection
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Circularity Profile:
N/A
Weight:
163.75 kg
Mercury Free:
Yes
Reach Free Of Svhc:
Yes
Noise Level:
6 dB NEMA ST-20 || 39 dB
Tap Loss:
110 no load (core loss) || 703 load loss (coil loss)
Product Or Component Type:
transformer
Efficiency:
98.31 % at 35 % load factor , 75.0°C
Reach Regulation:
Free of Substances of Very High Concern above the threshold
X/R Ratio:
1
Network Frequency:
60 Hz
Box Number:
18M
Toxic Heavy Metal Free:
Yes
Country of Origin:
United States
Rohs Exemption Information:
Yes
Halogen Content Performance:
Halogen free plastic parts product
Primary Operational Current:
36.08-36.08 A 72.17 A 30 kVA
Depth:
627 mm
[Ipk] Rated Peak Withstand Current:
2.41 kA
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 2 Hole Nema Pad primary 11.1 mm
Temperature Rise:
150°C || 220°C insulated
Average Ambient Air Temperature For Operation:
30°C
Phase:
3 phase
Secondary Voltage:
240 V delta || centre tap 120 V
Transformer Type:
energy efficient
Material:
aluminium
Device Application:
low voltage electrical distribution
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Continuous Thermal Current Rating Factor:
442 16.6 % || 525 25 % || 975 50 % || 1725 75 % || 2774 100 %
Primary Voltage:
480 V delta
Number Of Mounting Holes:
4 Ø: 13 mm
Sustainable Offer Status:
Green Premium product
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Rated Operational Power In Va:
30 kVA
Pvc Free:
Yes
Device Short Name:
DOE 2016
Eu Rohs Directive:
Compliant
Range Of Product:
Square D
Environmental Disclosure:
ENVPEP1604028EN
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
$3,348.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 30kVA, 480V primary (three wire), 240/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.23% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.
View AllClose