Schneider Electric

Schneider Electric EXN45T3155H Transformer, dry type, DOE 2016, 45kVA, 3 phase, 240V delta primary, 480Y/277V secondary, 19M, 150C rise

(No reviews yet) Write a Review
SKU:
EXN45T3155H
MPN:
EXN45T3155H
Condition:
New
Phase:
3 phase
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
Box Number:
19M
Secondary Voltage:
480Y/277 V
Rated Operational Power In Va:
45 kVA
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Efficiency:
98.48 % at 35 % load factor , 75.0°C
Noise Level:
6 dB NEMA ST-20 || 39 dB
Material:
aluminium
Inrush Current:
1350 A
Weight:
179.17 kg
Percentage Reactance:
0.0269
Transformer Type:
energy efficient
Ambient Air Temperature For Operation:
40-40°C
Device Application:
low voltage electrical distribution
Percentage Impedance Voltage:
0.0386
Depth:
659 mm
Type Of Cooling:
natural convection
Range Of Product:
Square D
[Ipk] Rated Peak Withstand Current:
1.40 kA
Continuous Thermal Current Rating Factor:
490 16.6 % || 656 25 % || 1547 50 % || 3034 75 % || 5115 100 %
Number Of Mounting Holes:
4 Ø: 13 mm
Tap Loss:
105 no load (core loss) || 1394 load loss (coil loss)
Temperature Rise:
150°C || 220°C insulated
Device Short Name:
DOE 2016
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
X/R Ratio:
1.07
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Average Ambient Air Temperature For Operation:
30°C
Electrical Connection:
2 Hole Nema Pad secondary 11.1 mm || 4 Hole Nema Pad sec - HO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Net Weight:
179.17 kg
Primary Operational Current:
108.25-108.25 A 54.13 A 45 kVA
Primary Voltage:
240 V delta
Product Or Component Type:
transformer
Network Frequency:
60 Hz
Country of Origin:
Mexico
$5,181.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 45kVA, 208V primary (three wire), 480Y/277V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.40% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.