Schneider Electric

Schneider Electric EXN75T3HBCU Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 80C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN75T3HBCU
MPN:
EXN75T3HBCU
Condition:
New
Toxic Heavy Metal Free:
Yes
Type Of Cooling:
natural convection
Rated Operational Power In Va:
75 kVA
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
Rohs Exemption Information:
Yes
Device Short Name:
DOE 2016
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
X/R Ratio:
2.03
Environmental Disclosure:
ENVPEP1604027EN
Country of Origin:
United States
Reach Free Of Svhc:
Yes
Net Weight:
312.98 kg
Primary Voltage:
480 V delta
Eu Rohs Directive:
Compliant
Efficiency:
98.74 % at 35 % load factor , 75.0°C
Range Of Product:
Square D
Circularity Profile:
N/A
Ambient Air Temperature For Operation:
40-40°C
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Ipk] Rated Peak Withstand Current:
3.71 kA
Secondary Voltage:
208Y/120 V
Sustainable Offer Status:
Green Premium product
Tap Loss:
142 no load (core loss) || 1687 load loss (coil loss)
Number Of Mounting Holes:
4 Ø: 13 mm
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Temperature Rise:
80°C || 220°C insulated
Primary Operational Current:
90.21-90.21 A 208.18 A 75 kVA
Network Frequency:
60 Hz
Mercury Free:
Yes
Material:
copper
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Depth:
697 mm
Percentage Reactance:
0.0522
Device Application:
low voltage electrical distribution
Noise Level:
44 dB || 6 dB NEMA ST-20
Average Ambient Air Temperature For Operation:
30°C
Inrush Current:
706 A
Transformer Type:
energy efficient
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Continuous Thermal Current Rating Factor:
644 16.6 % || 844 25 % || 1924 50 % || 3722 75 % || 6241 100 %
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Phase:
3 phase
Percentage Impedance Voltage:
0.0561
Product Or Component Type:
transformer
$12,483.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 75kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 80 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.60% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.