Schneider Electric

Schneider Electric EXN75T3HNLP Transformer, dry type, DOE 2016, 75kVA, 3 phase, 480V delta primary, 208Y/120V secondary, 20M, 150C rise, K13

(No reviews yet) Write a Review
SKU:
EXN75T3HNLP
MPN:
EXN75T3HNLP
Condition:
New
Noise Level:
44 dB || 6 dB NEMA ST-20
Halogen Content Performance:
Halogen free plastic parts product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Electrical Connection:
4 Hole Nema Pad secondary 11.1 mm || 6 Hole Nema Pad sec - XO 11.1 mm || 4 Hole Nema Pad primary 11.1 mm
Secondary Voltage:
208Y/120 V
Average Ambient Air Temperature For Operation:
30°C
Inrush Current:
771 A
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Circularity Profile:
N/A
Temperature Rise:
150°C || 220°C insulated
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Reach Free Of Svhc:
Yes
Material:
aluminium
Tap Loss:
153 no load (core loss) || 1933 load loss (coil loss)
Primary Operational Current:
90.21-90.21 A 208.18 A 75 kVA
Device Short Name:
DOE 2016
Net Weight:
263.08 kg
Depth:
697 mm
Continuous Thermal Current Rating Factor:
690 16.6 % || 947 25 % || 2335 50 % || 4648 75 % || 7885 100 %
Ambient Air Temperature For Operation:
40-40°C
Eu Rohs Directive:
Compliant
Toxic Heavy Metal Free:
Yes
Product Or Component Type:
transformer
Sustainable Offer Status:
Green Premium product
Mercury Free:
Yes
Number Of Mounting Holes:
4 Ø: 13 mm
Range Of Product:
Square D
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Type Of Cooling:
natural convection
Network Frequency:
60 Hz
Country of Origin:
Mexico
Primary Voltage:
480 V delta
Rohs Exemption Information:
Yes
Pvc Free:
Yes
Weight:
263.08 kg
X/R Ratio:
2.36
[Ipk] Rated Peak Withstand Current:
3.96 kA
Transformer Type:
energy efficient
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Rated Operational Power In Va:
75 kVA
Percentage Impedance Voltage:
0.0526
Device Application:
low voltage electrical distribution
Percentage Reactance:
0.0463
Box Number:
20M
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
$7,639.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 75kVA, 480V primary (three wire), 208Y/120V secondary (four wire) with aluminum windings with a 220 insulation system design for 150 degree C temperature rise, K-13 rated. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.60% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.