Schneider Electric

Schneider Electric EXN75T65HCU Transformer, dry type, DOE 2016, 75kVA, 3 phase, 600V delta primary, 208Y/120V secondary, 20M, 150C rise, Cu

(No reviews yet) Write a Review
SKU:
EXN75T65HCU
MPN:
EXN75T65HCU
Condition:
New
Reach Free Of Svhc:
Yes
Depth:
697 mm
Rated Operational Power In Va:
75 kVA
Percentage Impedance Voltage:
0.0467
Primary Operational Current:
72.17-72.17 A 208.18 A 75 kVA
Height:
851 mm
Number Of Mounting Holes:
4 Ø: 13 mm
Number Of Tap-Offs:
2 2.5 % FCAN || 4 2.5 % FCBN
Rohs Exemption Information:
Yes
Temperature Rise:
150°C || 220°C insulated
Secondary Voltage:
208Y/120 V
Noise Level:
44 dB || 6 dB NEMA ST-20
Toxic Heavy Metal Free:
Yes
Mounting Support:
floor || floor, with 7400FMB || ceiling, with 7400CMB18M19M20M || wall, with 7400WMB18M19M20M
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Tap Loss:
127 no load (core loss) || 2259 load loss (coil loss)
Continuous Thermal Current Rating Factor:
647 16.6 % || 915 25 % || 2360 50 % || 4769 75 % || 8141 100 %
Transformer Type:
energy efficient
Ambient Air Temperature For Operation:
40-40°C
Standards:
UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Sustainable Offer Status:
Green Premium product
Phase:
3 phase
Type Of Cooling:
natural convection
Device Short Name:
DOE 2016
[Uimp] Rated Impulse Withstand Voltage:
10 kV
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Net Weight:
297.56 kg
Material:
copper
Inrush Current:
951 A
Range Of Product:
Square D
Device Application:
low voltage electrical distribution
Percentage Reactance:
0.0363
Environmental Disclosure:
ENVPEP1604027EN
Country of Origin:
Mexico
Network Frequency:
60 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: Phenyl Glycidyl Ether, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Degree Of Protection:
UL type 2 || UL type 3R, with 7400WS18M19M20M
Electrical Connection:
4 Hole Nema Pad primary 11.1 mm
[Ipk] Rated Peak Withstand Current:
4.46 kA
Weight:
297.56 kg
Eu Rohs Directive:
Compliant
Mercury Free:
Yes
Average Ambient Air Temperature For Operation:
30°C
Circularity Profile:
N/A
Pvc Free:
Yes
Primary Voltage:
600 V delta
X/R Ratio:
1.24
Product Or Component Type:
transformer
$11,564.00

Description

EXN three phase low voltage dry type distribution transformers from Square D comply with DOE energy conservation standards and Natural Resources Canada (NRCan) minimum energy efficiency levels. This transformer is a 75kVA, 600V primary (three wire), 208Y/120V secondary (four wire) with copper windings with a 220 insulation system design for 150 degree C temperature rise. This transformer’s DOE 2016 and NRCan efficiency is a minimum of 98.60% at 35% loading and 75°C temperature. Terminals are designed to accommodate wire ranges sized for 125% of the secondary nameplate current and 250% of the primary nameplate current. The terminals allow for NEMA two hole lugs and wiring bending radius to align with the wire ranges and to allow for side and bottom access. Units are natural air cooled with exhaust vents located on the front only, allowing the transformers to be mounted with rear clearance to obstructions of ½ inch. Units are shipped as Type 2 for indoor installation, field convertible to Type 3R via weathershield for outdoor installation. The transformers are floor mounted but field accessories are available for wall or trapeze (ceiling) mounting. EX transformers have a low sound level, with a minimum of 3dB below NEMA Standard ST-20 requirements. Units are specifically designed to function with other Square D equipment; inrush is coordinated to meet identified breaker trip curves, and IZ levels allow for let through current to match AIR levels of panelboards. See product data sheets for these values.