Schneider Electric

Schneider Electric EZM1400FS Main fusible (Class T) switch unit, EZ Meter-Pak, 400A, 120/240VAC, 1ph/3W, 400A bus, OH/UG, Type 3R

(No reviews yet) Write a Review
SKU:
EZM1400FS
MPN:
EZM1400FS
Condition:
New
Bus Rated Current:
400 A
Eu Rohs Directive:
Compliant with Exemptions
Main Rated Current:
400 A
Product Or Component Type:
meter center main unit
Range Of Product:
EZ meter-pak
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty:
18 months
Service Feed Location:
OH || UG
Mercury Free:
Yes
Device Mounting:
surface
Depth:
11.50 in
Sustainable Offer Status:
Green Premium product
Rohs Exemption Information:
Yes
Wiring Configuration:
3-wire
Phase:
1 phase in || 1 phase out
[Ue] Rated Operational Voltage:
120/240 V AC
Provided Equipment:
main switch 1 ) 2P 400 A || closing plate
Enclosure Material:
painted steel
Circularity Profile:
N/A
Country of Origin:
United States
Product Certifications:
UL Listed
Nema Degree Of Protection:
NEMA 3R
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP2011003
Electrical Connection:
lugs 1 AWG 6...300 kcmil aluminium/copper) ground || lugs 1 AWG 1...600 kcmil aluminium/copper) line || lugs 2 AWG 1...250 kcmil aluminium/copper) line || lugs 1 AWG 1...600 kcmil aluminium/copper) neutral || lugs 2 AWG 1...250 kcmil aluminium/copper
Main Type:
Main Fusible Switch
$3,989.00

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main fusible switch provides 1 phase in, 1 phase out for a 3 wire configuration. It accepts 120/240VAC incoming service from OH or UG feeds. The unit is rated for 400A with the busbar rated for 400A. With a 300V Class T fuse, the short circuit current rating is 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.
View AllClose