Schneider Electric

Schneider Electric EZM31200FST Main fusible (Class T) switch unit, EZ Meter-Pak, 1200A, 240VAC max, 3ph/4W, 1200A bus, OH, Type 3R

(No reviews yet) Write a Review
SKU:
EZM31200FST
MPN:
EZM31200FST
Condition:
New
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Enclosure Material:
painted steel
Electrical Connection:
lugs 1 AWG 6...300 kcmil aluminium/copper) ground || lugs 4 AWG 3/0...500 kcmil aluminium/copper) line || lugs 4 AWG 3/0...500 kcmil aluminium/copper) neutral
Sustainable Offer Status:
Green Premium product
Eu Rohs Directive:
Compliant with Exemptions
Country of Origin:
United States
Warranty:
18 months
Depth:
13.69 in
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Bus Rated Current:
1200 A
Provided Equipment:
main switch 1 ) 3P 1200 A 100 kA || closing plate
Circularity Profile:
N/A
Range Of Product:
EZ meter-pak
Service Feed Location:
OH
Nema Degree Of Protection:
NEMA 3R
Environmental Disclosure:
ENVPEP2011003
Mercury Free:
Yes
Wiring Configuration:
4-wire
Product Certifications:
UL Listed
Product Or Component Type:
meter center main unit
Phase:
3 phase in || 3 phase out
Main Rated Current:
1200 A
Device Mounting:
surface
Main Type:
Main Fusible Switch
$14,906.00

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main fusible switch provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from OH feeds. The unit is rated for 1200A with the busbar rated for 1200A. With a 300V Class T fuse, the short circuit current rating is 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.