Schneider Electric

Schneider Electric EZM31200GCBTMS Main circuit breaker unit, EZ Meter-Pak, 1200A, 240VAC max, 3ph/4W, 1200A bus, 65kA, OH, Type 3R, ERMS

(No reviews yet) Write a Review
SKU:
EZM31200GCBTMS
MPN:
EZM31200GCBTMS
Condition:
New
Circularity Profile:
N/A
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Device Mounting:
surface
Rohs Exemption Information:
Yes
Electrical Connection:
lugs 4 AWG 3/0...500 kcmil copper or aluminium) || lugs 1 AWG 6...300 kcmilground
Nema Degree Of Protection:
NEMA 3R
Product Certifications:
UL Listed
Product Or Component Type:
meter center main unit
Provided Equipment:
circuit-breaker 1 ) 3P 1200 A 65 kA main supply, ready assembled || closing plate
Wiring Configuration:
4-wire
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Bus Rated Current:
1200 A
Service Feed Location:
OH
Main Rated Current:
1200 A
Country of Origin:
France
Range Of Product:
EZ meter-pak
Type Of Installation:
indoor/outdoor
Phase:
3 phase in || 3 phase out
Environmental Disclosure:
ENVPEP2011003
Eu Rohs Directive:
Compliant with Exemptions
Enclosure Material:
painted steel
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Main Type:
Main Circuit Breaker
Sustainable Offer Status:
Green Premium product
Depth:
13.63 in
Mercury Free:
Yes
$38,182.50

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from OH feeds. The unit is rated for 1200A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 65kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.
View AllClose