Schneider Electric

Schneider Electric EZM31200GCBUMS Main circuit breaker unit, EZ Meter-Pak, 1200A, 240VAC max, 3ph/4W, 1200A bus, 65kA, UG, Type 3R, ERMS

(No reviews yet) Write a Review
SKU:
EZM31200GCBUMS
MPN:
EZM31200GCBUMS
Condition:
New
Environmental Disclosure:
ENVPEP2011003
Phase:
3 phase in || 3 phase out
Sustainable Offer Status:
Green Premium product
Service Feed Location:
UG
Circularity Profile:
N/A
Device Mounting:
surface
Main Rated Current:
1200 A
Enclosure Material:
painted steel
Type Of Installation:
indoor/outdoor
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
Main Type:
Main Circuit Breaker
Mercury Free:
Yes
Range Of Product:
EZ meter-pak
Depth:
13.63 in
Nema Degree Of Protection:
NEMA 3R
Provided Equipment:
circuit-breaker 1 ) 3P 1200 A 65 kA main supply, ready assembled || closing plate
Wiring Configuration:
4-wire
Country of Origin:
Mexico
Product Certifications:
UL Listed
Bus Rated Current:
1200 A
Product Or Component Type:
meter center main unit
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Electrical Connection:
lugs 4 AWG 3/0...500 kcmil copper or aluminium) || lugs 1 AWG 6...300 kcmilground
California Proposition 65:
WARNING: This product can expose you to chemicals including: lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
$33,816.80

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from UG feeds. The unit is rated for 1200A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 65kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.
View AllClose