Schneider Electric

Schneider Electric EZM31600GCBCMS Main circuit breaker unit, EZ Meter-Pak, 1600A, 240VAC max, 3ph/4W, 1200A bus, 65kA, OH/UG, Type 3R, ERMS

(No reviews yet) Write a Review
SKU:
EZM31600GCBCMS
MPN:
EZM31600GCBCMS
Condition:
New
Enclosure Material:
painted steel
Rohs Exemption Information:
Yes
Wiring Configuration:
4-wire
Circularity Profile:
N/A
Bus Rated Current:
1200 A
Nema Degree Of Protection:
NEMA 3R
Product Or Component Type:
meter center main unit
Range Of Product:
EZ meter-pak
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Type Of Installation:
indoor/outdoor
Provided Equipment:
circuit-breaker 1 ) 3P 1600 A 65 kA main supply, ready assembled || closing plate
Eu Rohs Directive:
Compliant with Exemptions
Sustainable Offer Status:
Green Premium product
Country of Origin:
Mexico
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Phase:
3 phase in || 3 phase out
Service Feed Location:
OH || UG
Product Certifications:
UL Listed
Mercury Free:
Yes
Environmental Disclosure:
ENVPEP2011003
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
lugs 1 AWG 6...300 kcmilground || lugs 6 AWG 1/0...750 kcmil copper or aluminium)
Main Rated Current:
1600 A
Depth:
18.31 in
Main Type:
Main Circuit Breaker
Device Mounting:
surface
$55,481.40

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from OH or UG feeds. The unit is rated for 1600A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 65kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.
View AllClose