Schneider Electric

Schneider Electric EZM31600JCBCMS Main circuit breaker unit, EZ Meter-Pak, 1600A, 240VAC max, 3ph/4W, 1200A bus, 100kA, OH/UG, Type 3R, ERMS

(No reviews yet) Write a Review
SKU:
EZM31600JCBCMS
MPN:
EZM31600JCBCMS
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Provided Equipment:
circuit-breaker 1 ) 3P 1600 A 100 kA main supply, ready assembled || closing plate
Country of Origin:
Mexico
Depth:
18.31 in
Service Feed Location:
OH || UG
Phase:
3 phase in || 3 phase out
Circularity Profile:
N/A
Main Type:
Main Circuit Breaker
Electrical Connection:
lugs 1 AWG 6...300 kcmilground || lugs 6 AWG 1/0...750 kcmil copper or aluminium)
Sustainable Offer Status:
Green Premium product
Product Or Component Type:
meter center main unit
Mercury Free:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Certifications:
UL Listed
Wiring Configuration:
4-wire
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Rohs Exemption Information:
Yes
Nema Degree Of Protection:
NEMA 3R
Type Of Installation:
indoor/outdoor
Bus Rated Current:
1200 A
Environmental Disclosure:
ENVPEP2011003
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Enclosure Material:
painted steel
Main Rated Current:
1600 A
Device Mounting:
surface
Range Of Product:
EZ meter-pak
$54,877.50

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from OH or UG feeds. The unit is rated for 1600A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.