Schneider Electric

Schneider Electric EZM31600JCBUMS Main circuit breaker unit, EZ Meter-Pak, 1600A, 240VAC max, 3ph/4W, 1200A bus, 100kA, UG, Type 3R, ERMS

(No reviews yet) Write a Review
SKU:
EZM31600JCBUMS
MPN:
EZM31600JCBUMS
Condition:
New
Country of Origin:
Mexico
Service Feed Location:
UG
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Main Type:
Main Circuit Breaker
Eu Rohs Directive:
Compliant with Exemptions
Product Certifications:
UL Listed
Phase:
3 phase in || 3 phase out
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
[Ue] Rated Operational Voltage:
208Y/120 V AC || 240/120 V delta AC
Provided Equipment:
circuit-breaker 1 ) 3P 1600 A 100 kA main supply, ready assembled || closing plate
Enclosure Material:
painted steel
Nema Degree Of Protection:
NEMA 3R
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
meter center main unit
Bus Rated Current:
1200 A
Range Of Product:
EZ meter-pak
Electrical Connection:
lugs 1 AWG 6...300 kcmilground || lugs 6 AWG 2...750 kcmil copper or aluminium)
Main Rated Current:
1600 A
Depth:
18.31 in
Type Of Installation:
indoor/outdoor
Wiring Configuration:
4-wire
Device Mounting:
surface
$54,742.50

Description

Square D EZ Meter-Pak meter centers provide reliable, versatile, and compact multi metering equipment for multi unit residential and commercial construction. The main devices are available as main circuit breakers, main fusible switches, or main lug terminal boxes. The compact footprint makes them easier to handle and install.  Visi-Tite nuts eliminate the need for time-consuming torque readings when connecting devices.  External mounting channels permit immediate installation with no disassembly or adjustment required. EZM main devices are suitable for use as service equipment with required grounding and bonding. This main circuit breaker provides 3 phases in, 3 phases out for a 4 wire configuration. It accepts 208Y/120VAC and 240/120VAC delta incoming service from UG feeds. The unit is rated for 1600A with the busbar rated for 1200A. With ERMS (energy reducing maintenance switch), it has a short circuit current rating of 100kA. The enclosure is painted steel Type 3R. This EZ Meter-Pak meter center complies with UL standards.
View AllClose