Schneider Electric

Schneider Electric GB2CS05 TeSys GB2 thermal magnetic circuit protector, 1 P, 0.5 A, Id = 3.3 A

(No reviews yet) Write a Review
SKU:
GB2CS05
MPN:
GB2CS05
Condition:
New
Product Name:
TeSys GB2
[Uimp] Rated Impulse Withstand Voltage:
4 kV IEC 60947-2
Ambient Air Temperature For Storage:
-40-80°C
Device Short Name:
GB2
Poles Description:
1P
Mechanical Durability:
8000 cycles
Control Type:
toggle
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Mounting Mode:
by clips
Operating Altitude:
9842.52 ft (3000 m)
Reach Free Of Svhc:
Yes
Country of Origin:
France
Circularity Profile:
N/A
Utilisation Category:
category A IEC 60947-2 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
Depth:
67 mm
Trip Unit Technology:
thermal-magnetic
Sustainable Offer Status:
Green Premium product
Electrical Durability:
8000 cycles
Environmental Disclosure:
ENVPEP2306023
Fire Resistance:
960°C IEC 60695-2-1
Weight:
0.055 kg
Mounting Support:
plate || rail
Connections - Terminals:
connector 1 0.75-6 mm²solid without cable end || connector 2 0.75-4 mm²solid without cable end || connector 1 0.75-4 mm²flexible with cable end || connector 2 0.75-2.5 mm²flexible with cable end
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Product Or Component Type:
circuit breaker
Warranty:
18 months
Quantity Per Set:
set of 6
Net Weight:
0.055 kg
Network Frequency:
50/60 Hz IEC 60947-2
Toxic Heavy Metal Free:
Yes
[Ue] Rated Operational Voltage:
250 V AC 50/60 Hz IEC 60947-2 || 48 V DC
Line Rated Current:
0.5 A
Rohs Exemption Information:
Yes
Range:
TeSys
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 110 V AC 50/60 Hz IEC 60947-2 || 25 % 230/240 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
1.2 N.m connector
Protective Treatment:
TC
Mechanical Robustness:
shocks 22 Gn for 20 ms IEC 60068-2-27 || vibrations 5 Gn, 5...110 Hz IEC 60068-2-6
Width:
15 mm
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2
Network Type:
AC/DC
Mercury Free:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Ip Degree Of Protection:
IP20 IEC 60529
Ambient Air Temperature For Operation:
-20-60°C
9 Mm Pitches:
2
Mounting Position:
vertical || horizontal
$43.60

Description

TeSys GB circuit breaker, 1 pole (1P), 0.5A/250V, low tripping threshold, for the protection of industrial equipment control circuits. It provides thermal magnetic protection with a magnetic tripping level at 3.3A (6 In) and breaking capacity Icu 50kA@240V. It can also be used for protection of DC loads up to 0.5A/48V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (15mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 6 units. It conforms to IEC 60947-1 and IEC 60947-2, Green Premium product (RoHS/REACh).
View AllClose