Schneider Electric

Schneider Electric GB2DB06 TeSys GB2 thermal magnetic circuit protector, 2 P, 1 A, Id = 14 A

(No reviews yet) Write a Review
SKU:
GB2DB06
MPN:
GB2DB06
Condition:
New
Network Type:
AC/DC
Weight:
0.115 kg
Eu Rohs Directive:
Compliant
Range:
TeSys
Network Frequency:
50/60 Hz IEC 60947-2
Utilisation Category:
category A IEC 60947-2 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
Mounting Mode:
by clips
Mercury Free:
Yes
Magnetic Tripping Current:
14-14 A
Protective Treatment:
TC
Operating Altitude:
9842.52 ft (3000 m)
Breaking Capacity:
50 kA Icu 110 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 1.5 kA Icu 24 V DC IEC 60947-2 || 1 kA Icu 48 V DC IEC 60947-2
Trip Unit Technology:
thermal-magnetic
Product Or Component Type:
circuit breaker
9 Mm Pitches:
4
Sustainable Offer Status:
Green Premium product
Product Name:
TeSys GB2
California Proposition 65:
WARNING: Cancer - www.P65Warnings.ca.gov
Mechanical Robustness:
shocks 22 Gn for 20 ms IEC 60068-2-27 || vibrations 5 Gn, 5...110 Hz IEC 60068-2-6
Electrical Durability:
8000 cycles
Ip Degree Of Protection:
IP20 IEC 60529
Poles Description:
2P
Ambient Air Temperature For Storage:
-40-80°C
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Connections - Terminals:
connector 1 0.75-6 mm²solid without cable end || connector 2 0.75-4 mm²solid without cable end || connector 1 0.75-4 mm²flexible with cable end || connector 2 0.75-2.5 mm²flexible with cable end
Depth:
70 mm
Device Short Name:
GB2
Mounting Position:
vertical || horizontal
Line Rated Current:
0.0416666666666667
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
N/A
Tightening Torque:
1.2 N.m connector
Control Type:
toggle
Toxic Heavy Metal Free:
Yes
Power Dissipation Per Pole:
2 W
[Ue] Rated Operational Voltage:
415 V AC 50/60 Hz IEC 60947-2 || 48 V DC
Country of Origin:
France
Reach Free Of Svhc:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Net Weight:
0.115 kg
Mechanical Durability:
8000 cycles
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity:
25 % 230/240 V AC 50/60 Hz IEC 60947-2 || 50 % 110 V AC 50/60 Hz IEC 60947-2 || 25 % 400/415 V AC 50/60 Hz IEC 60947-2
Mounting Support:
plate || rail
Ambient Air Temperature For Operation:
-20-60°C
$93.00

Description

TeSys GB circuit breaker, 2 poles (2P), 1A/415V, for the protection of industrial equipment control circuits. It provides thermal-magnetic protection with a magnetic tripping level at 14A (13 In) and breaking capacity Icu 50kA@415V. It can also be used for protection of DC loads up to 1A/48V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (30mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 3 units. It conforms to IEC 60947-1 and IEC 60947-2, Green Premium product (RoHS/REACh).