Schneider Electric

Schneider Electric GV2LE05 TeSys GV2 Manual Starter and Protector, magnetic circuit protector, toggle switch, 1 A, screw clamp terminals

(No reviews yet) Write a Review
SKU:
GV2LE05
MPN:
GV2LE05
Condition:
New
Sustainable Offer Status:
Green Premium product
[Ith] Conventional Free Air Thermal Current:
1 A IEC 60947-4-1
Range:
TeSys Deca
Operating Altitude:
6561.68 ft (2000 m)
Device Application:
motor protection
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Network Type:
AC
Trip Unit Technology:
magnetic
Product Name:
TeSys GV2
Circularity Profile:
ENVEOLI121004
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
IP20 IEC 60529
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Ik Degree Of Protection:
IK04
Country of Origin:
France
Motor Power Kw:
0.25-0.25 kW 400/415 V AC 50/60 Hz || 0.37-0.37 kW 400/415 V AC 50/60 Hz || 0.37-0.37 kW 500 V AC 50/60 Hz || 0.55-0.55 kW 690 V AC 50/60 Hz || 0.75-0.75 kW 690 V AC 50/60 Hz
Rohs Exemption Information:
Yes
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Device Short Name:
GV2LE
Ambient Air Temperature For Operation:
-20-60°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Rated Duty:
continuous IEC 60947-4-1
Ambient Air Temperature For Storage:
-40-80°C
Net Weight:
0.33 kg
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Magnetic Tripping Current:
13-13 A
Mechanical Robustness:
shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
Fire Resistance:
960°C IEC 60695-2-11
Warranty:
18 months
Network Frequency:
50/60 Hz IEC 60947-2
Control Type:
toggle
Line Rated Current:
0.0416666666666667
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Climatic Withstand:
IACS E10
Mechanical Durability:
100000 cycles
Weight:
0.33 kg
Poles Description:
3P
Color:
dark grey
Tightening Torque:
1.7 N.m screw clamp terminal
Power Dissipation Per Pole:
1.8 W
Eu Rohs Directive:
Compliant with Exemptions
Suitability For Isolation:
yes IEC 60947-1§ 7-1-6
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
$290.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25-0.37kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD05 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose