Schneider Electric

Schneider Electric GV2LE08 TeSys GV2 Manual Starter and Protector, magnetic circuit protector, toggle switch, 4 A, screw clamp terminals

(No reviews yet) Write a Review
SKU:
GV2LE08
MPN:
GV2LE08
Condition:
New
Depth:
78.5 mm
Circularity Profile:
ENVEOLI121004
Tightening Torque:
1.7 N.m screw clamp terminal
Rated Duty:
continuous IEC 60947-4-1
Product Certifications:
CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA || IECEE CB Scheme
Operating Altitude:
6561.68 ft (2000 m)
Product Name:
TeSys GV2
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Poles Description:
3P
Ik Degree Of Protection:
IK04
Width:
45 mm
Eu Rohs Directive:
Compliant with Exemptions
Weight:
0.33 kg
Motor Power Kw:
1.5-1.5 kW 400/415 V AC 50/60 Hz || 1.5-1.5 kW 500 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 3-3 kW 690 V AC 50/60 Hz
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Fire Resistance:
960°C IEC 60695-2-11
Country of Origin:
France
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Ith] Conventional Free Air Thermal Current:
4 A IEC 60947-4-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Color:
dark grey
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Net Weight:
0.33 kg
Network Type:
AC
Device Application:
motor protection
Magnetic Tripping Current:
51-51 A
Product Or Component Type:
motor circuit breaker
Ambient Air Temperature For Storage:
-40-80°C
Ip Degree Of Protection:
IP20 IEC 60529
Mechanical Durability:
100000 cycles
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Line Rated Current:
0.166666666666667
Device Short Name:
GV2LE
Suitability For Isolation:
yes IEC 60947-1§ 7-1-6
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Operation:
-20-60°C
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Power Dissipation Per Pole:
1.8 W
Control Type:
toggle
Network Frequency:
50/60 Hz IEC 60947-2
Warranty:
18 months
Environmental Disclosure:
ENVPEP121004
Trip Unit Technology:
magnetic
$294.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 4A/690V, for 3-phase motor applications 1.1-1.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 100kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD08 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose