Schneider Electric

Schneider Electric GV2LE16 TeSys GV2 Manual Starter and Protector, magnetic circuit protector, toggle switch, 14 A, screw clamp terminals

(No reviews yet) Write a Review
SKU:
GV2LE16
MPN:
GV2LE16
Condition:
New
Width:
45 mm
Network Frequency:
50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-2
Network Type:
AC
Circularity Profile:
ENVEOLI121004
Net Weight:
0.33 kg
Breaking Capacity:
100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity:
100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 50 % 400/415 V AC 50/60 Hz IEC 60947-2 || 50 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
Device Short Name:
GV2LE
Eu Rohs Directive:
Compliant with Exemptions
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1 || AC-3e IEC 60947-4-1
Product Certifications:
CCC || UL || CSA || EAC || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA || IECEE CB Scheme
Power Dissipation Per Pole:
1.8 W
Ambient Air Temperature For Operation:
-20-60°C
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Line Rated Current:
14 A
[Ith] Conventional Free Air Thermal Current:
14 A IEC 60947-4-1
Poles Description:
3P
Control Type:
toggle
Environmental Disclosure:
ENVPEP121004
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Color:
dark grey
Device Application:
motor protection
Depth:
78.5 mm
Fixing Mode:
35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Suitability For Isolation:
yes IEC 60947-1§ 7-1-6
Weight:
0.33 kg
Motor Power Kw:
5.5-5.5 kW 400/415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz || 9-9 kW 690 V AC 50/60 Hz || 11-11 kW 690 V AC 50/60 Hz
Ambient Air Temperature For Storage:
-40-80°C
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Rated Duty:
continuous IEC 60947-4-1
[Ui] Rated Insulation Voltage:
690 V AC 50/60 Hz IEC 60947-2
Tightening Torque:
1.7 N.m screw clamp terminal
Product Or Component Type:
motor circuit breaker
Range:
TeSys Deca
Trip Unit Technology:
magnetic
Operating Altitude:
6561.68 ft (2000 m)
Magnetic Tripping Current:
170-170 A
Climatic Withstand:
IACS E10
Mechanical Durability:
100000 cycles
Fire Resistance:
960°C IEC 60695-2-11
Warranty:
18 months
Electrical Durability:
100000 cycles AC-3 415 V In || 100000 cycles AC-3e 415 V In
Ip Degree Of Protection:
IP20 IEC 60529
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
$302.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 14A/690V, for 3-phase motor applications 5.5kW@400V. It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 15kA@400V. Connection by screw clamp terminals. Start-stop control by toggle guaranteed for 100 000 cycles AC-3. To complete motor protection, use in association with a thermal overload relay LRD16 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
View AllClose