Schneider Electric

Schneider Electric GV4P02N6 Motor circuit breaker, TeSys GV4, 3P, 2A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4P02N6
MPN:
GV4P02N6
Condition:
New
Trip Unit Technology:
electronic || thermal-magnetic
Color:
Gray RAL 7016)
Line Rated Current:
0.0833333333333333
Range Of Product:
TeSys GV4
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Circularity Profile:
ENVEOLI1704004EN
Ip Degree Of Protection:
IP40 IEC 60529
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85°C
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Width:
81 mm
Ambient Air Temperature For Operation:
-25-70°C
Power Dissipation Per Pole:
4.6 W
Depth:
165 mm
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Poles Description:
3P
Weight:
1.6 kg
Rohs Exemption Information:
Yes
Range:
TeSys Deca
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Net Weight:
1.6 kg
Warranty:
18 months
Pvc Free:
Yes
Phase Failure Sensitivity:
yes IEC 60947-4-1
Halogen Content Performance:
Halogen free plastic parts product
Mechanical Durability:
40000 cycles
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Maximum Operating Rate:
25 cyc/h
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Or Component Type:
motor circuit breaker
Pollution Degree:
3
Device Short Name:
GV4P
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Operating Position:
any position
Suitability For Isolation:
yes IEC 60947-1
Connections - Terminals:
lugs-ring terminals
Mercury Free:
Yes
Motor Power Kw:
0.25-0.25 kW 400...415 V AC 50/60 Hz || 0.37-0.37 kW 400...415 V AC 50/60 Hz || 0.55-0.55 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 400...415 V AC 50/60 Hz || 0.37-0.37 kW 500 V AC 50/60 Hz || 0.55-0.55 kW 500 V AC 50/60 Hz || 0.75-0.75 kW 500 V AC
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Magnetic Tripping Current:
34-34 A
Environmental Disclosure:
ENVPEP1704004EN
Operating Altitude:
5000 m
Sustainable Offer Status:
Green Premium product
Control Type:
rotary handle
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
$1,192.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 2A/690V, for protection of 3-phase motors 0.25-0.75kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 0.8-2A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose