Schneider Electric

Schneider Electric GV4P12N6 Motor circuit breaker, TeSys GV4, 3P, 12.5A, Icu 50kA, thermal magnetic, lugs terminals

(No reviews yet) Write a Review
SKU:
GV4P12N6
MPN:
GV4P12N6
Condition:
New
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Rohs Exemption Information:
Yes
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Depth:
165 mm
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Pvc Free:
Yes
Fire Resistance:
960°C IEC 60695-2-11
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Trip Unit Technology:
electronic || thermal-magnetic
Range Of Product:
TeSys GV4
Operating Altitude:
5000 m
Product Or Component Type:
motor circuit breaker
Line Rated Current:
12.5 A
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Product Name:
TeSys GV4 || TeSys Deca
Sustainable Offer Status:
Green Premium product
Maximum Operating Rate:
25 cyc/h
Phase Failure Sensitivity:
yes IEC 60947-4-1
Net Weight:
1.6 kg
Warranty:
18 months
Circularity Profile:
ENVEOLI1704004EN
Magnetic Tripping Current:
212-212 A
Ik Degree Of Protection:
IK07 IEC 62262
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Range:
TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Weight:
1.6 kg
Connections - Terminals:
lugs-ring terminals
Device Short Name:
GV4P
Control Type:
rotary handle
Climatic Withstand:
IACS E10
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Poles Description:
3P
Environmental Disclosure:
ENVPEP1704004EN
Motor Power Kw:
3-3 kW 400...415 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz || 4-4 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 400...415 V AC 50/60 Hz || 5.5-5.5 kW 5
Ip Degree Of Protection:
IP40 IEC 60529
Mechanical Durability:
40000 cycles
Power Dissipation Per Pole:
4.6 W
Suitability For Isolation:
yes IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
Connection Pitch:
27 mm without spreaders || 35 mm with spreaders
Halogen Content Performance:
Halogen free plastic parts product
Operating Position:
any position
$795.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 12.5A/690V, for protection of 3-phase motors 3-5.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 5-12.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose