Schneider Electric

Schneider Electric GV4P50B Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 25kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4P50B
MPN:
GV4P50B
Condition:
New
Device Application:
motor protection
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Circularity Profile:
ENVEOLI1704004EN
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Rated Duty:
continuous IEC 60947-4-1
Magnetic Tripping Current:
850-850 A
Environmental Disclosure:
ENVPEP1704004EN
Phase Failure Sensitivity:
yes IEC 60947-4-1
Halogen Content Performance:
Halogen free plastic parts product
Fire Resistance:
960°C IEC 60695-2-11
Ip Degree Of Protection:
IP40 IEC 60529
Control Type:
rotary handle
Width:
81 mm
Range:
TeSys Deca
Eu Rohs Directive:
Compliant with Exemptions
Power Dissipation Per Pole:
4.6 W
Operating Position:
any position
Line Rated Current:
50 A
Motor Power Kw:
11-11 kW 400...415 V AC 50/60 Hz || 15-15 kW 500 V AC 50/60 Hz || 18.5-18.5 kW 660...690 V AC 50/60 Hz || 15-15 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 400...415 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 18.5-18.5 kW 500 V AC 50/60 Hz |
Range Of Product:
TeSys GV4
Country of Origin:
Mexico
Ambient Air Temperature For Storage:
-50-85°C
Depth:
165 mm
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Electrical Durability:
20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Maximum Operating Rate:
25 cyc/h
Mercury Free:
Yes
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Weight:
1.6 kg
Warranty:
18 months
Product Name:
TeSys GV4 || TeSys Deca
Poles Description:
3P
Breaking Capacity:
50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 35 kA 208Y/120 V AC 50/60 Hz UL 60947 || 35 kA 240 V AC 50/60 Hz U
Ik Degree Of Protection:
IK07 IEC 62262
Rohs Exemption Information:
Yes
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Trip Unit Technology:
thermal-magnetic || electronic
Color:
Gray RAL 7016)
Pvc Free:
Yes
Sustainable Offer Status:
Green Premium product
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Device Short Name:
GV4P
Climatic Withstand:
IACS E10
$645.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).