Schneider Electric GV4P50N6 Motor circuit breaker, TeSys GV4, 3P, 50A, Icu 50kA, thermal magnetic, lugs terminals
Schneider Electric
$1,192.50
TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Thermal protection adjustable by dials with a setting current Ir in range 20-50A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
- Fire Resistance:
- 960°C IEC 60695-2-11
- Magnetic Tripping Current:
- 850-850 A
- Country of Origin:
- Poland
- Suitability For Isolation:
- yes IEC 60947-1
- Maximum Operating Rate:
- 25 cyc/h
- Pollution Degree:
- 3
- Climatic Withstand:
- IACS E10
- Eu Rohs Directive:
- Compliant with Exemptions
- Ambient Air Temperature For Operation:
- -25-70°C
- Weight:
- 1.6 kg
- Environmental Disclosure:
- ENVPEP1704004EN
- Device Application:
- motor protection
- Rated Duty:
- continuous IEC 60947-4-1
- Sustainable Offer Status:
- Green Premium product
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Rohs Exemption Information:
- Yes
- Depth:
- 165 mm
- Mechanical Robustness:
- vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
- Connection Pitch:
- 27 mm without spreaders || 35 mm with spreaders
- Breaking Capacity:
- 100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
- Halogen Content Performance:
- Halogen free plastic parts product
- Power Dissipation Per Pole:
- 4.6 W
- Ik Degree Of Protection:
- IK07 IEC 62262
- Color:
- Gray RAL 7016)
- Device Short Name:
- GV4P
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Pvc Free:
- Yes
- Operating Altitude:
- 5000 m
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1
- Standards:
- CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
- Ambient Air Temperature For Storage:
- -50-85°C
- Ip Degree Of Protection:
- IP40 IEC 60529
- Product Name:
- TeSys GV4 || TeSys Deca
- Trip Unit Technology:
- electronic || thermal-magnetic
- Tightening Torque:
- 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
- [Ith] Conventional Free Air Thermal Current:
- 115 A IEC 60947-4-1
- Operating Position:
- any position
- Phase Failure Sensitivity:
- yes IEC 60947-4-1
- Warranty:
- 18 months
- [Ui] Rated Insulation Voltage:
- 800 V AC 50/60 Hz IEC 60947-2
- Mercury Free:
- Yes
- Product Certifications:
- IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Control Type:
- rotary handle
- Poles Description:
- 3P
- Mechanical Durability:
- 40000 cycles