Schneider Electric

Schneider Electric GV4P80B Motor circuit breaker, TeSys GV4, 3P, 80A, Icu 25kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4P80B
MPN:
GV4P80B
Condition:
New
Trip Unit Technology:
electronic || thermal-magnetic
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Climatic Withstand:
IACS E10
Depth:
165 mm
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Power Dissipation Per Pole:
4.6 W
Operating Position:
any position
Operating Altitude:
5000 m
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Control Type:
rotary handle
Rohs Exemption Information:
Yes
Range:
TeSys Deca
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Country of Origin:
Mexico
Ik Degree Of Protection:
IK07 IEC 62262
Device Application:
motor protection
Net Weight:
1.6 kg
Motor Power Kw:
37-37 kW 400...415 V AC 50/60 Hz || 45-45 kW 500 V AC 50/60 Hz || 22-22 kW 400...415 V AC 50/60 Hz || 30-30 kW 500 V AC 50/60 Hz || 37-37 kW 660...690 V AC 50/60 Hz || 45-45 kW 660...690 V AC 50/60 Hz || 55-55 kW 660...690 V AC 50/60 Hz || 30-30 kW 4
Warranty:
18 months
Phase Failure Sensitivity:
yes IEC 60947-4-1
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Rated Duty:
continuous IEC 60947-4-1
Breaking Capacity:
50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 35 kA 208Y/120 V AC 50/60 Hz UL 60947 || 35 kA 240 V AC 50/60 Hz U
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Circularity Profile:
ENVEOLI1704004EN
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Product Name:
TeSys GV4 || TeSys Deca
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Short Name:
GV4P
Color:
Gray RAL 7016)
Fire Resistance:
960°C IEC 60695-2-11
Ip Degree Of Protection:
IP40 IEC 60529
Weight:
1.6 kg
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Storage:
-50-85°C
Mechanical Durability:
40000 cycles
Ambient Air Temperature For Operation:
-25-70°C
Suitability For Isolation:
yes IEC 60947-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Sustainable Offer Status:
Green Premium product
Halogen Content Performance:
Halogen free plastic parts product
Electrical Durability:
14000 cycles AC-3 440 V In/2 || 7000 cycles AC-3 440 V In
Magnetic Tripping Current:
1360-1360 A
$745.00

Description

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose