Schneider Electric GV4PB50B Motor circuit breaker, TeSys Deca, 3P, 50A, Icu 25kA, thermal magnetic, multifunction, UL489
Schneider Electric
$424.00
TeSys GV motor circuit breaker, 3 poles (3P), 50A/690V, for protection of 3-phase motors 11-22kW@400V. Multifunction circuit breaker UL489 compliant, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 20-50A, a selectable tripping class 10 or 20, rated tripping current 125%, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL 489, CSA C22.2 N°5), Green Premium compliant (RoHS/REACh).
- Fire Resistance:
- 960°C IEC 60695-2-11
- Color:
- Gray RAL 7016)
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ics] Rated Service Short-Circuit Breaking Capacity:
- 100 % 220/240 V AC 50/60 Hz IEC 60947-2 || 100 % 380/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2
- Ik Degree Of Protection:
- IK07 IEC 62262
- Power Dissipation Per Pole:
- 4.6 W
- Ip Degree Of Protection:
- IP40 IEC 60529
- Warranty:
- 18 months
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mechanical Durability:
- 40000 cycles
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Operating Position:
- any position
- Connections - Terminals:
- EverLink BTR screw connectors top) 1 1.5-70 mm² - rigid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - rigid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
- Mercury Free:
- Yes
- Device Short Name:
- GV4PB
- Suitability For Isolation:
- yes IEC 60947-1
- Range:
- TeSys Deca
- Electrical Durability:
- 20000 cycles AC-3 440 V In/2 || 10000 cycles AC-3 440 V In
- Product Or Component Type:
- motor circuit breaker
- Eu Rohs Directive:
- Compliant with Exemptions
- Net Weight:
- 1.45 kg
- Climatic Withstand:
- IACS E10
- Poles Description:
- 3P
- Rohs Exemption Information:
- Yes
- Utilisation Category:
- category A IEC 60947-2 || AC-3 IEC 60947-4-1
- Standards:
- EN/IEC 60947-1 || EN/IEC 60947-2 || EN/IEC 60947-4-1 || UL 489 || CSA C22.2 No 5
- [Ui] Rated Insulation Voltage:
- 800 V AC 50/60 Hz IEC 60947-2
- Maximum Operating Rate:
- 25 cyc/h
- Weight:
- 1.45 kg
- Circularity Profile:
- ENVEOLI1704004EN
- Ambient Air Temperature For Operation:
- -25-70°C
- Pvc Free:
- Yes
- Pollution Degree:
- 3
- Device Application:
- motor protection
- Operating Altitude:
- 5000 m
- Range Of Product:
- TeSys GV4
- Environmental Disclosure:
- ENVPEP1704004EN
- Product Certifications:
- IEC || UL || CSA
- Sustainable Offer Status:
- Green Premium product
- Tightening Torque:
- 9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
- Trip Unit Technology:
- thermal-magnetic || electronic
- Ambient Air Temperature For Storage:
- -50-85°C
- Rated Duty:
- continuous IEC 60947-4-1
- Breaking Capacity:
- 35 kA SCCR 240 V AC 60 Hz UL 489 || 18 kA SCCR 480Y/277 V AC 60 Hz UL 489 || 14 kA SCCR 600Y/347 V AC 60 Hz UL 489 || 50 kA Icu 220/240 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 380/415 V AC 50/60 Hz IEC 60947-2 || 20 kA Icu 440 V AC 50/60 Hz IEC 60947-
- Depth:
- 116 mm
- Mechanical Robustness:
- vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27