Schneider Electric

Schneider Electric GV4PE03N Motor circuit breaker, TeSys GV4, 3P, 3.5A, Icu 50kA, thermal magnetic, Everlink terminals

(No reviews yet) Write a Review
SKU:
GV4PE03N
MPN:
GV4PE03N
Condition:
New
Product Or Component Type:
motor circuit breaker
Utilisation Category:
category A IEC 60947-2 || AC-3 IEC 60947-4-1
Motor Power Kw:
0.55-0.55 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 400...415 V AC 50/60 Hz || 0.75-0.75 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 500 V AC 50/60 Hz || 1.1-1.1 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 660...690 V AC 50/60 Hz || 1.5-1.5 kW 500 V AC 50/60 Hz
Color:
Gray RAL 7016)
Device Application:
motor protection
Range:
TeSys Deca
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Weight:
1.45 kg
Line Rated Current:
3.5 A
Ambient Air Temperature For Operation:
-25-70°C
Operating Position:
any position
Mechanical Durability:
40000 cycles
Operating Altitude:
5000 m
Net Weight:
1.45 kg
Suitability For Isolation:
yes IEC 60947-1
Device Short Name:
GV4PE
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Magnetic Tripping Current:
59-59 A
Pollution Degree:
3
Product Name:
TeSys GV4 || TeSys Deca
Depth:
116 mm
Product Certifications:
IEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Rated Duty:
continuous IEC 60947-4-1
Tightening Torque:
9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Breaking Capacity:
100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz
Pvc Free:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
[Ith] Conventional Free Air Thermal Current:
115 A IEC 60947-4-1
Standards:
CSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
[Ue] Rated Operational Voltage:
690 V AC 50/60 Hz IEC 60947-2
Electrical Durability:
40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Maximum Operating Rate:
25 cyc/h
Environmental Disclosure:
ENVPEP1704004EN
Width:
81 mm
Range Of Product:
TeSys GV4
Mechanical Robustness:
vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Ik Degree Of Protection:
IK07 IEC 62262
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
[Ui] Rated Insulation Voltage:
800 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI1704004EN
Rohs Exemption Information:
Yes
Phase Failure Sensitivity:
yes IEC 60947-4-1
Climatic Withstand:
IACS E10
Fire Resistance:
960°C IEC 60695-2-11
Connections - Terminals:
EverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Country of Origin:
Poland
$1,042.50

Description

TeSys GV motor circuit breaker, 3 poles (3P), 3.5A/690V, for protection of 3-phase motors 0.55-1.5kW@400V. It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 1.4-3.5A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Additional protections have fixed pick-up and include short time delay protection Isd at 13 Ir, phase unbalance and loss protection, ground fault protection. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
View AllClose